Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
PLoS One ; 17(1): e0261853, 2022.
Article in English | MEDLINE | ID: covidwho-1622346

ABSTRACT

Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) is used worldwide to test and trace the spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). "Extraction-less" or "direct" real time-reverse transcription polymerase chain reaction (RT-PCR) is a transparent and accessible qualitative method for SARS-CoV-2 detection from nasopharyngeal or oral pharyngeal samples with the potential to generate actionable data more quickly, at a lower cost, and with fewer experimental resources than full RT-qPCR. This study engaged 10 global testing sites, including laboratories currently experiencing testing limitations due to reagent or equipment shortages, in an international interlaboratory ring trial. Participating laboratories were provided a common protocol, common reagents, aliquots of identical pooled clinical samples, and purified nucleic acids and used their existing in-house equipment. We observed 100% concordance across laboratories in the correct identification of all positive and negative samples, with highly similar cycle threshold values. The test also performed well when applied to locally collected patient nasopharyngeal samples, provided the viral transport media did not contain charcoal or guanidine, both of which appeared to potently inhibit the RT-PCR reaction. Our results suggest that direct RT-PCR assay methods can be clearly translated across sites utilizing readily available equipment and expertise and are thus a feasible option for more efficient COVID-19 coronavirus disease testing as demanded by the continuing pandemic.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction/methods , Reverse Transcription/genetics , SARS-CoV-2/genetics , COVID-19/virology , Feasibility Studies , Humans , Nasopharynx/virology , Pandemics/prevention & control , Sensitivity and Specificity , Serologic Tests/methods , Specimen Handling/methods
2.
Sci Rep ; 11(1): 21385, 2021 11 01.
Article in English | MEDLINE | ID: covidwho-1493218

ABSTRACT

Shortages of reverse transcriptase (RT)-polymerase chain reaction (PCR) reagents and related equipment during the COVID-19 pandemic have demonstrated the need for alternative, high-throughput methods for severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2)-mass screening in clinical diagnostic laboratories. A robust, SARS-CoV-2 RT-loop-mediated isothermal amplification (RT-LAMP) assay with high-throughput and short turnaround times in a clinical laboratory setting was established and compared to two conventional RT-PCR protocols using 323 samples of individuals with suspected SARS-CoV-2 infection. Limit of detection (LoD) and reproducibility of the isolation-free SARS-CoV-2 RT-LAMP test were determined. An almost perfect agreement (Cohen's kappa > 0.8) between the novel test and two classical RT-PCR protocols with no systematic difference (McNemar's test, P > 0.05) was observed. Sensitivity and specificity were in the range of 89.5 to 100% and 96.2 to 100% dependent on the reaction condition and the RT-PCR method used as reference. The isolation-free RT-LAMP assay showed high reproducibility (Tt intra-run coefficient of variation [CV] = 0.4%, Tt inter-run CV = 2.1%) with a LoD of 95 SARS-CoV-2 genome copies per reaction. The established SARS-CoV-2 RT-LAMP assay is a flexible and efficient alternative to conventional RT-PCR protocols, suitable for SARS-CoV-2 mass screening using existing laboratory infrastructure in clinical diagnostic laboratories.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , COVID-19/epidemiology , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , Pandemics , Reverse Transcriptase Polymerase Chain Reaction/methods , SARS-CoV-2/genetics , COVID-19/virology , Genome, Viral , Humans , Infection Control/methods , Limit of Detection , Mass Screening/methods , RNA, Viral/genetics , RNA, Viral/isolation & purification , RNA-Directed DNA Polymerase/genetics , Reproducibility of Results , Reverse Transcription/genetics , Sensitivity and Specificity
3.
Jpn J Infect Dis ; 74(4): 325-332, 2021 Jul 21.
Article in English | MEDLINE | ID: covidwho-1380108

ABSTRACT

Studies describing reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay-based infection control strategies (LAMP-based ICSs) for coronavirus disease 2019 (COVID-19) are limited. We reviewed the medical records of cases in which RT-LAMP was performed. Standard ICSs and LAMP-based ICSs were implemented during the study period. The strategies were intended to impose longer periods of infection control precautions (ICPs) for specific patients, such as those with a history of exposure to COVID-19 patients and/or bilateral ground glass opacities (bGGO) on chest computed tomography (CT). Of 212 patients, which included 13 confirmed COVID-19 patients in the diagnostic cohort, exposure to COVID-19 patients (P <0.0001) and chest CT bGGO (P = 0.0022) were identified as significant predictors of COVID-19. In the 173 hospitalized patients in which the results of the first RT-LAMP were negative, the duration of ICPs was significantly longer in patients with exposure to COVID-19 and/or a high clinical index of suspicion and patients with bGGO than in the remaining patients (P = 0.00046 and P = 0.0067, respectively). Additionally, no confirmed COVID-19 cases indicating nosocomial spread occurred during the study period. Establishing a comprehensive system that combines rational LAMP-based ICSs with standard ICSs might be useful for preventing nosocomial spread.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , COVID-19/virology , Infection Control/methods , Reverse Transcription/genetics , SARS-CoV-2/genetics , Adult , Clinical Laboratory Techniques/methods , Female , Hospitals , Humans , Male , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , RNA, Viral/genetics , Sensitivity and Specificity , Tokyo , Young Adult
4.
PLoS One ; 16(3): e0248042, 2021.
Article in English | MEDLINE | ID: covidwho-1115310

ABSTRACT

A newly identified coronavirus, designated as severe acute respiratory syndrome coronavirus 2 (SARS CoV-2), has spread rapidly from its epicenter in China to more than 150 countries across six continents. In this study, we have designed three reverse-transcription loop-mediated isothermal amplification (RT-LAMP) primer sets to detect the RNA-dependent RNA polymerase (RdRP), Envelope (E) and Nucleocapsid protein (N) genes of SARS CoV-2. For one tube reaction, the detection limits for five combination SARS CoV-2 LAMP primer sets (RdRP/E, RdRP/N, E/N, RdRP/E/N and RdRP/N/Internal control (actin beta)) were evaluated with a clinical nasopharyngeal swab sample. Among the five combination, the RdRP/E and RdRP/N/IC multiplex LAMP assays showed low detection limits. The sensitivity and specificity of the RT-LAMP assay were evaluated and compared to that of the widely used Allplex™ 2019-nCoV Assay (Seegene, Inc., Seoul, South Korea) and PowerChek™ 2019-nCoV Real-time PCR kit (Kogenebiotech, Seoul, South Korea) for 130 clinical samples from 91 SARS CoV-2 patients and 162 NP specimens from individuals with (72) and without (90) viral respiratory infections. The multiplex RdRP (FAM)/N (CY5)/IC (Hex) RT-LAMP assay showed comparable sensitivities (RdRP: 93.85%, N: 94.62% and RdRP/N: 96.92%) to that of the Allplex™ 2019-nCoV Assay (100%) and superior to those of PowerChek™ 2019-nCoV Real-time PCR kit (RdRP: 92.31%, E: 93.85% and RdRP/E: 95.38%).


Subject(s)
COVID-19/diagnosis , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , SARS-CoV-2/genetics , COVID-19/genetics , COVID-19 Testing/methods , Clinical Laboratory Techniques/methods , Coronavirus Infections/virology , DNA Primers/genetics , Humans , Nucleocapsid Proteins/genetics , RNA, Viral/genetics , Real-Time Polymerase Chain Reaction/methods , Reverse Transcription/genetics , SARS-CoV-2/pathogenicity , Sensitivity and Specificity
5.
J Vis Exp ; (168)2021 02 03.
Article in English | MEDLINE | ID: covidwho-1090278

ABSTRACT

Traditional methods to detect and quantify nucleic acids rely on polymerase chain reaction (PCR) and require the use of expensive thermocyclers with integrated fluorescence detection of amplicons. Isothermal nucleic acid amplification technologies eliminate the need for thermal cycling; however, fluorescence-based detection of products is still required for real-time, quantitative results. Several portable isothermal heaters with integrated fluorescence detection are now commercially available; however, the cost of these devices remains a significant barrier to widespread adoption in resource-limited settings. Described here is a protocol for the design and assembly of a modular, low-cost fluorimeter constructed from off-the-shelf components. Enclosed in a compact 3D printed housing, the fluorimeter is designed to be placed atop a commercially available heat block holding a PCR tube. The fluorimeter described here was optimized to detect fluorescein isothiocyanate (FITC) dye, but the system can be modified for use with dyes commonly used as reporters in real-time nucleic acid amplification reactions. Clinical applicability of the system is demonstrated by performing real-time nucleic acid detection with two isothermal amplification technologies: recombinase polymerase amplification (RPA) for detection of positive control DNA provided in a commercial kit and reverse transcription loop-mediated isothermal amplification (RT-LAMP) for detection of clinically meaningful levels of SARS-CoV-2 RNA.


Subject(s)
Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , Nucleic Acids/genetics , Printing, Three-Dimensional , Reverse Transcription/genetics , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , COVID-19/genetics , Health Resources , Humans , RNA, Viral/genetics , RNA, Viral/isolation & purification , Real-Time Polymerase Chain Reaction/methods
6.
J Transl Med ; 19(1): 74, 2021 02 16.
Article in English | MEDLINE | ID: covidwho-1088600

ABSTRACT

BACKGROUND: COVID-19 has spread rapidly around the world, affecting a large percentage of the population. When lifting certain mandatory measures for an economic restart, robust surveillance must be established and implemented, with nucleic acid detection for SARS-CoV-2 as an essential component. METHODS: We tried to develop a one-tube detection platform based on RT-RPA (Reverse Transcription and Recombinase Polymerase Isothermal Amplification) and DNA Endonuclease-Targeted CRISPR Trans Reporter (DETECTR) technology, termed OR-DETECTR, to detect SARS-CoV-2. We designed RT-RPA primers of the RdRp and N genes following the SARS-CoV-2 gene sequence. We optimized reaction components so that the detection process could be carried out in one tube. Specificity was demonstrated by detecting nucleic acid samples from pseudoviruses from seven human coronaviruses and Influenza A (H1N1). Clinical samples were used to validate the platform and all results were compared to rRT-PCR. RNA standards and pseudoviruses diluted by different gradients were used to demonstrate the detection limit. Additionally, we have developed a lateral flow assay based on OR-DETECTR for detecting COVID-19. RESULTS: The OR-DETECTR detection process can be completed in one tube, which takes approximately 50 min. This method can specifically detect SARS-CoV-2 from seven human coronaviruses and Influenza A (H1N1), with a low detection limit of 2.5 copies/µl input (RNA standard) and 1 copy/µl input (pseudovirus). Results of six samples from SARS-CoV-2 patients, eight samples from patients with fever but no SARS-CoV-2 infection, and one mixed sample from 40 negative controls showed that OR-DETECTR is 100% consistent with rRT-PCR. The lateral flow assay based on OR-DETECTR can be used for the detection of COVID-19, and the detection limit is 2.5 copies/µl input. CONCLUSIONS: The OR-DETECTR platform for the detection of COVID-19 is rapid, accurate, tube closed, easy-to-operate, and free of large instruments.


Subject(s)
COVID-19 Testing/methods , COVID-19/diagnosis , COVID-19/virology , CRISPR-Cas Systems/genetics , Real-Time Polymerase Chain Reaction/methods , Reverse Transcription/genetics , SARS-CoV-2/isolation & purification , Base Sequence , Humans , Limit of Detection , RNA, Viral/genetics , Reference Standards , SARS-CoV-2/genetics
7.
J Cell Mol Med ; 24(20): 12054-12064, 2020 10.
Article in English | MEDLINE | ID: covidwho-755303

ABSTRACT

Cell-free microRNAs (miRNAs) are transferred in disease state including inflammatory lung diseases and are often packed into extracellular vesicles (EVs). To assess their suitability as biomarkers for community-acquired pneumonia (CAP) and severe secondary complications such as sepsis, we studied patients with CAP (n = 30), sepsis (n = 65) and healthy volunteers (n = 47) subdivided into a training (n = 67) and a validation (n = 75) cohort. After precipitating crude EVs from sera, associated small RNA was profiled by next-generation sequencing (NGS) and evaluated in multivariate analyses. A subset of the thereby identified biomarker candidates was validated both technically and additionally by reverse transcription quantitative real-time PCR (RT-qPCR). Differential gene expression (DGE) analysis revealed 29 differentially expressed miRNAs in CAP patients when compared to volunteers, and 25 miRNAs in patients with CAP, compared to those with sepsis. Sparse partial-least discriminant analysis separated groups based on 12 miRNAs. Three miRNAs proved as a significant biomarker signature. While expression levels of miR-1246 showed significant changes with an increase in overall disease severity from volunteers to CAP and to sepsis, miR-193a-5p and miR-542-3p differentiated patients with an infectious disease (CAP or sepsis) from volunteers. Cell-free miRNAs are potentially novel biomarkers for CAP and may help to identify patients at risk for progress to sepsis, facilitating early intervention and treatment.


Subject(s)
Circulating MicroRNA/blood , Community-Acquired Infections/diagnosis , Community-Acquired Infections/genetics , Pneumonia/diagnosis , Pneumonia/genetics , Sepsis/blood , Sepsis/complications , Aged , Aged, 80 and over , Circulating MicroRNA/genetics , Community-Acquired Infections/blood , Gene Expression Regulation , Humans , Immunity, Humoral/genetics , Middle Aged , Multivariate Analysis , Pneumonia/blood , Pneumonia/complications , Reproducibility of Results , Reverse Transcription/genetics , Sepsis/genetics
8.
PLoS One ; 16(1): e0245164, 2021.
Article in English | MEDLINE | ID: covidwho-1013227

ABSTRACT

Rapid diagnosis is an important intervention in managing the Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) outbreak. Real time reverse transcription polymerase chain reaction (RT-qPCR) remains the primary means for diagnosing the new virus strain but it is time consuming and costly. Recombinase polymerase amplification (RPA) is an isothermal amplification assay that does not require a PCR machine. It is an affordable, rapid, and simple assay. In this study, we developed and optimized a sensitive reverse transcription (RT)-RPA assay for the rapid detection of SARS-CoV-2 using SYBR Green I and/or lateral flow (LF) strip. The analytical sensitivity and specificity of the RT-RPA assay were tested by using 10-fold serial diluted synthetic RNA and genomic RNA of similar viruses, respectively. Clinical sensitivity and specificity of the RT-RPA assay were carried out using 78 positive and 35 negative nasopharyngeal samples. The detection limit of both RPA and RT-qPCR assays was 7.659 and 5 copies/µL RNA, respectively with no cross reactivity with other viruses. The clinical sensitivity and specificity of RT-RPA were 98% and 100%, respectively. Our study showed that RT-RPA represents a viable alternative to RT-qPCR for the detection of SARS-CoV-2, especially in areas with limited infrastructure.


Subject(s)
COVID-19/diagnosis , Real-Time Polymerase Chain Reaction/methods , SARS-CoV-2/genetics , COVID-19/genetics , Humans , Malaysia/epidemiology , Nucleic Acid Amplification Techniques/methods , Recombinases/genetics , Recombinases/metabolism , Reverse Transcription/genetics , SARS-CoV-2/pathogenicity , Sensitivity and Specificity
9.
Clin Chim Acta ; 511: 143-148, 2020 Dec.
Article in English | MEDLINE | ID: covidwho-844315

ABSTRACT

BACKGROUND: The coronavirus disease 2019 (COVID-19) has become a pandemic. Reverse transcription quantitative PCR (RT-qPCR) has played a vital role in the diagnosis of COVID-19, but the rates of false negatives is not ideal in dealing with this highly infectious virus. It is thus necessary to systematically evaluate the clinical performance of the single-, dual-, triple-target detection kits to guide the clinical diagnosis of this disease. METHODS: A series of reference materials calibrated by droplet digital PCR (ddPCR) and 57 clinical samples were used to evaluate the clinical performance of six single-, dual-, triple-target SARS-CoV-2 nucleic acid detection kits based on RT-qPCR. RESULTS: The dual-target kits, kit B and kit C had the highest and the lowest detection sensitivity, which was 125 copies/mL and 4000 copies/mL, respectively. Among the 57 clinical samples from patients with COVID-19, 47 were tested positive by the kit B, while 35, 29, 28, 30, and 29 were found positive by the kits A, C, D, E, and F, respectively. The number of targets in a detection kit is not a key factor affecting sensitivity, while the amount of sample loading may influence the performance of a detection kit. CONCLUSIONS: This study provides a guide when choosing or developing a nucleic acid detection kit for the diagnosis of COVID-19. Also, the absolute-quantification feature and high-sensitivity performance of ddPCR, suggesting that it can be used to review clinically suspected samples.


Subject(s)
COVID-19/diagnosis , COVID-19/genetics , Reverse Transcriptase Polymerase Chain Reaction/methods , Reverse Transcriptase Polymerase Chain Reaction/standards , SARS-CoV-2/genetics , Adolescent , Adult , Aged , Aged, 80 and over , Cohort Studies , Female , Humans , Male , Middle Aged , Reverse Transcription/genetics , SARS-CoV-2/isolation & purification , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL